Sign In | Join Free | My udpf.com |
|
Brand Name : XG
Model Number : VS1
Certification : CCC,ISO
Place of Origin : XIAN
MOQ : 1
Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability : 2000 SETS
Delivery Time : 3-7 DAYS
Packaging Details : WOODEN CASE
Model : VS1…….
Type : indoor
Rated Voltage : 3.6KV 6.6KV 7.2kV, 12kV, 17.5kV, 24kV, 36kV, 40.5kV
Rated Current : 400A 630A, 1250A, 1600A, 2000A, 2500A, 3150A,
Frequency : 50/60Hz
Poles Number : 3
1. VS1 12KV 11KV Vacuum Circuit Breaker
ZN63(VS1)-12 Series Embedded Poles Type Indoor HV Vacuum Circuit Breaker, adopt solid insulation structure, use of advanced solid epoxy sealing technology, the first time, the vacuum interrupter. A leading electrical circuit. insulation and other support to become an integrated combination of solid seal pole. Successfully from a fundamental solution of the vacuum breaker gas environment, tolerance issues, make it more broad. Integrated solid-pole closure of the fluent use of a self-ventilation technology, cleverly solved the structure of solid insulation caused by heat dissipation.
2.Product parameter
ITEM | UNIT | DATA | ||
Rated voltage | kV | 12 | ||
Rated current | A | 1250 | ||
Rated frequency | Hz | 50 | ||
Rated insulation level | Lightning impulse withstand voltage | Phase to phase, phase to earth | kV | 75 |
Insulating distance of contact | 85 | |||
1min power frequency withstand voltage | Phase to phase, phase to earth | 42 | ||
Insulating distance of contact | 49 | |||
4s rated short time withstand current | kA | 31.5 | ||
Rated short circuit break current | / | 31.5 | ||
Rated peak value withstand current | / | 80 | ||
Rated short circuit making current | / | 80 | ||
Rated operation sequence | O-0.3s-CO-180s-CO | |||
Break times of rated short circuit current | Times | 50 | ||
Mechanical life | 20000 | |||
Break current of rated different phases earth fault | kA | 27.4 | ||
Break current of rated single capacitor bank | A | 400 | ||
Break current of rated back to back capacitor bank | 400 | |||
Rated open operation voltage/current | V/A | DC(AC)220/1.1 DC(AC)110/2.2 | ||
Rated making operation voltage/current | DC(AC)220/1.1 DC(AC)110/2.2 | |||
Release work current of rated transient over current | A | 5 | ||
Rated circuit of secondary circuit | V | DC(AC)220 DC(AC)110 | ||
Rated voltage of energy storage motor | DC(AC)220 DC(AC)110 | |||
Rated output power of energy storage motor | W | 50 | ||
Energy storage time | s | ≤10 | ||
1min power frequency withstand voltage of secondary circuit | V | 2000 | ||
Insulating distance of contact | mm | 11±1 | ||
Overtravel of contact | 3+1 0 | |||
Center distance between different poles | 210±1 | |||
Allow abrasion thick of contact | 3 | |||
Average opening speed | m/s | 1.2±0.2 | ||
Average closing speed | 0.7±0.2 | |||
Contact closing jump time | ms | ≤2 | ||
Close/open synchronized of three phases | ≤2 | |||
Main circuit resistance | μΩ | ≤55 | ||
Opening time | ms | 25~60 | ||
Closing time | 35~75 | |||
Operation characteristic of operation mechanism | 65%~120% rated voltage | Reliable open/close | ||
≤30% rated voltage | Can not open |
3. Application
Rated voltage(12kV)
Rated short-time P.F. withstand voltage(1min.)(42kV)
Rated lightning impulse withstand voltage(peak)(75kV)
Rated power frequency(50/60Hz)
Altitude: 1000m;
Ambient temperature: -25 ~+40 ;
Relative humidity: daily average 95 , monthly average 90 ;
Earthquake intensity: 8 degree;
Applicable occasions should free from inflammables, explosives, corrosives
4.Technical detail
5.Contact us
Emma ma
Phone/wechat/whatsapp: 0086 13319220197
Wechat ID: Sales_E
Email: emma@zgxgdn.com; 40516034@qq.com;
QQ: 574306294
![]() |
3 Poles Drawout 12KV 11KV Vacuum Circuit Breaker Images |